Function Description
The main process that calculates various dimensions and areas of the Pallet AS/RS.
It sequentially calculates storage capacity, rack dimensions, bay pitch, tier configuration, required spaces, floor area, virtual floor area, number of firewalls, layout area, etc.
Arguments
None (uses variables within the class)
Return Value
Type: None (Sub)
Description: Calculation results are displayed in respective TextBoxes
Processing Flow
- Storage Capacity Calculation:
- Columns = Units × 2
- PL Storage Capacity = Columns × Bays × Tiers
- Rack Total Width Calculation:
- Crane Aisle Width = PL Width + 200
- Rack Total Width = (PL Width + 100) × 2 + Crane Aisle Width
- Required Width = Rack Total Width + Adjacent C × 2
- Bay Pitch Calculation:
- Bay Pitch = Pillar Width + PL Depth + Rack C × 2
- Rack Length Calculation:
- Rack Total Length = Bay Pitch × Bays + Rack C
- Required Length Calculation:
- Required Length = Rack Total Length + Rack Rear Length + Maint. Aisle + I/O Conveyor Length + Handling Aisle
- Tier Configuration Calculation:
- Top Tier = PL Total Height + Lift C + Reinforcement Thickness + 220 (Minimum value 1600)
- Tier With Reinforcement = PL Total Height + Lift C + Reinforcement Thickness + Lift C + Cantilever Thickness
- Number of Tiers With Reinforcement = Int(Tiers / 3)
- Tier Without Reinforcement = PL Total Height + Lift C + Cantilever Thickness
- Number of Tiers Without Reinforcement = Tiers - Number of Tiers With Reinforcement - 1
- Rack Total Height / Required Height Calculation:
- Rack Total Height = Minimum Height + (Tier With Reinforcement × Number of Tiers With Reinforcement) + (Tier Without Reinforcement × Number of Tiers Without Reinforcement) + Top Tier
- Required Height = Rack Total Height + Ceiling C
- Required Area Per Unit Calculation:
- Required Area Per Unit = Int(Required Width × Required Length / 1000²)
- Virtual Floor Calculation:
- Top Tier Cantilever Upper Surface Height = Rack Total Height - Top Tier
- Virtual Floors = Int(Top Tier Cantilever Upper Surface Height / 5000)
- Virtual Floor Area = Virtual Floors × (Rack Total Width × Rack Total Length)
- Virtual Floor Area Per Unit = Int(Virtual Floor Area / 1000²)
- Layout Area Calculation:
- Layout Width = (Rack Total Width + Adjacent C) × Units + Adjacent C
- Total Floor Area = ((Layout Width × Required Length) × Units) / 1000²
- Total Virtual Floor Area = Virtual Floor Area Per Unit × Units
- Firewall Calculation:
- Area for Firewall Judgement = Total Floor Area + Total Virtual Floor Area
- Number of Firewalls = Int(Area for Firewall Judgement / 1500)
- Firewall Thickness = 150
- Layout Area = ((Layout Width + Number of Firewalls × (Firewall Thickness + 200)) × Required Length) / 1000²
Special Notes:
This function is the core of the logistics equipment space calculation. It also automatically calculates the required number of firewalls based on building standards.
Intermediate results are displayed in TextBoxes at each calculation stage, allowing the designer to verify the calculation process.