Calculation Method and Firewalls (Virtual Floors)
Storage capacity per unit block = Columns × Bays × Tiers.
Entering system blocks, bays, and tiers calculates total storage capacity and automatically determines required installation floor footprint.
Modifying rack specification Tera Settings and clicking "Start Calculation (Re-calculate)" updates calculations reflecting revised settings.
A firewall is required for every 1,500 m², with virtual floor area added at 5 m height increments.
For example:
Top cantilever elevation under 5 m = No virtual floor addition.
Top cantilever elevation 5 m to under 10 m = Virtual floor = Rack installation area (excluding handling aisles and inspection walkways).
Top cantilever elevation 10 m to under 15 m = Virtual floor = Rack installation area × 2.
A firewall is legally required for every 1,500 m² of combined "Actual Floor Area + Virtual Floor Area".